- In OSS, after selecting the "Settings" icon, set the parameters as shown below. Set the parameters one at a time, i.e. after each parameter change, confirm its setting with the "Yes" button. This setting is valid for the case when overflows are disabled. Note: please remember to set the LoadFirstControl parameter to "Single Phase Enabled".
- If you want to enable unlimited overflows, set the "Set Exportlimit" parameter to "Off".
-
If you want to enable partial overflows, you must have firmware version 050510 installed on the inverter. Furthermore, in the "Set Exportlimit" parameter setting, you need to set a numerical value according to the allowed overflows. The value refers to the rated power of the inverter (example: if you want to set the overflow size of 4 kW for the SPH10000 TL3 BH-X inverter, set the numerical value to 40).